Sale!

UNIVERSAL INDICATOR SOLUTION PH 4.0-10.0

450.00850.00

-10%

Characteristics of Universal Indicator Solution pH 4.0-10.0

  • Appearance: Clear, colorless liquid with a slight yellow tint
  • pH Range: 4.0 to 10.0
  • Chemical Composition: A mixture of several pH indicators (such as methyl red, bromothymol blue, and phenolphthalein)
  • Solubility: Water-soluble
  • Density: Approximately 1.0 g/cm³
  • Storage Conditions: Store in a cool, dry place away from direct sunlight and in tightly sealed containers
  • Shelf Life: Stable for long-term storage under recommended conditions
Add to Cart
UNIVERSAL INDICATOR SOLUTION PH 4.0-10.0
UNIVERSAL INDICATOR SOLUTION PH 4.0-10.0
450.00850.00

Free Nationwide shipping on all orders

Guaranteed Safe Checkout

Universal Indicator Solution pH 4.0-10.0 is a water-based solution designed to demonstrate the pH level of various substances. It is a blend of several indicators that show a range of colors corresponding to pH values between 4.0 and 10.0. This makes it ideal for use in testing the acidity or alkalinity of solutions in various scientific, educational, and industrial applications.

Applications of Universal Indicator Solution pH 4.0-10.0

1. Laboratory Applications

  • pH Measurement in Solutions:
    Universal Indicator Solution is commonly used in laboratory settings to measure the pH of various aqueous solutions. The solution changes color based on the pH, providing a visual representation of whether a solution is acidic, neutral, or alkaline.
  • Acid-Base Titrations:
    This indicator is frequently used in acid-base titrations to identify the endpoint of a titration, where the pH shifts dramatically. The color change helps determine the equivalence point between the acid and base.
  • Buffer Solution Testing:
    It is utilized to test the pH of buffer solutions and to verify their capacity to maintain a consistent pH when acidic or basic substances are added.

2. Educational and Demonstration Purposes

  • Classroom Experiments:
    Universal Indicator Solution is widely used in educational settings to demonstrate pH testing to students. It is ideal for illustrating the concepts of acidity and alkalinity, showing the full range of the pH scale with clear color changes.
  • Demonstrating Chemical Reactions:
    This solution is often used to showcase how different chemicals react when combined, highlighting the changes in pH that occur during various chemical reactions.

3. Environmental and Industrial Testing

  • Water Quality Testing:
    Universal Indicator Solution is commonly used in environmental science to assess the pH of water sources. This is crucial for determining water quality, as the pH level can impact aquatic life and the effectiveness of water treatments.
  • Soil Testing in Agriculture:
    In agriculture, the solution is used to assess soil pH, which affects plant growth and nutrient availability. The indicator helps determine whether the soil is too acidic or alkaline and assists in making adjustments for optimal plant health.

4. Food and Beverage Industry

  • pH Control in Food Production:
    In the food industry, controlling pH is vital for product consistency, safety, and preservation. Universal Indicator Solution can be used to monitor the pH of food products during production and ensure they meet the required standards.

5. Pharmaceutical and Cosmetic Applications

  • Formulation Testing:
    Universal Indicator Solution is employed in the pharmaceutical and cosmetic industries to test the pH of formulations such as creams, lotions, and lotions, ensuring they are safe for use and compatible with skin and mucous membranes.

Safety Guidelines for Handling Universal Indicator Solution pH 4.0-10.0

1. Hazards

  • Non-Toxic and Safe:
    Universal Indicator Solution is generally non-toxic and considered safe for use in laboratory and educational settings. However, the solution may cause mild irritation if it comes into contact with the eyes or skin.
  • Potential Staining:
    The solution may stain clothing and surfaces. It is important to handle the solution with care to avoid spills on fabrics or sensitive surfaces.

2. Personal Protective Equipment (PPE)

  • Gloves:
    Wear gloves when handling Universal Indicator Solution to avoid skin contact and potential staining. It is advisable to use nitrile or latex gloves to ensure safety during handling.
  • Eye Protection:
    Always wear safety goggles to protect your eyes from accidental splashes. If there is any risk of large quantities spilling, use a face shield for additional protection.
  • Lab Coat/Protective Clothing:
    A lab coat or protective clothing is essential to prevent staining or accidental contact with the solution. It is especially important in laboratory or industrial settings.

3. Handling and Storage

  • Handling Tips:
    When using the Universal Indicator Solution, handle it with care to avoid spillage. Use a dropper or pipette to dispense the solution accurately. Always return the bottle to a storage area after use to avoid contamination.
  • Storage:
    Store Universal Indicator Solution in a cool, dry location away from direct sunlight. Ensure the container is tightly sealed to prevent evaporation and contamination.
  • Avoid Cross-Contamination:
    When using the solution in various tests or experiments, ensure that all equipment is clean and free from other chemicals that could interfere with the results.

4. Spill and Leak Management

  • Spill Response:
    In the event of a spill, immediately clean up the solution with paper towels or absorbent cloth. Clean the affected area with soap and water to remove any residue and prevent staining.
  • Waste Disposal:
    Dispose of the Universal Indicator Solution according to local regulations. Generally, it can be diluted and safely disposed of down the drain with plenty of water, but confirm with local waste disposal guidelines.

5. First Aid Measures

  • Skin Contact:
    If the solution comes into contact with the skin, wash the affected area immediately with soap and water. Prolonged contact should be avoided to prevent any irritation or staining.
  • Eye Contact:
    In case of eye contact, flush the eyes with copious amounts of water for at least 15 minutes. If irritation persists, seek medical attention.
  • Inhalation:
    If inhaled in large quantities, move to fresh air immediately. While the solution is generally non-hazardous in normal use, it is always advisable to ensure good ventilation in the work area.
  • Ingestion:
    If ingested, rinse the mouth thoroughly with water. While the solution is non-toxic, avoid swallowing large quantities. If symptoms persist, seek medical advice.

Additional information

WeightN/A
Quantity

100ML, 500ML, 5L

Reviews

There are no reviews yet.

Be the first to review “UNIVERSAL INDICATOR SOLUTION PH 4.0-10.0”

Your email address will not be published. Required fields are marked *